Ratermann Manufacturing, Inc. Customer Service 1-800-264-7793 y Email [email protected] y Order Online at Web Store www.rmiorder.com 9A-13 DEWAR & MEDICAL GAS LABELS, 360˚ TAPE Your Industrial Cryogenic DOT-4L 360˚ Tape per Recommendation of CGA C-7 2014, Appendix F To Order Custom Print 360˚ Dewar Industrial or Medical Tape please see 7A 27-28. For all Dewar Valve Labels, please see 7A-32. GHS Compliant DOT-4L Body Labels – Industrial and Medical 14” x 11” Dewar Body Labels NITROGEN REFRIGERATED LIQUID NF UN 1977 IF INHALED: Remove person to fresh air and keep comfortable for breathing. IF ON SKIN: Thaw frosted parts with lukewarm water. Do not rub affected area. Get immediate medical advice/attention. RX only. Administration of Nitrogen may be hazardous or contraindicated. For use only by or under the supervision of a licensed practitioner who is experienced in the use and administration of Nitrogen and is familiar with the indications, effects, dosages, methods, and frequency and duration of administration, and with the hazards, contraindications and side effects, and the precautions to be taken. CONTAINS REFRIGERATED GAS; MAY CAUSE CRYOGENIC BURNS OR INJURY. MAY DISPLACE OXYGEN AND CAUSE RAPID SUFFOCATION. Do not handle until all safety precautions have been read and understood. Use and store only outdoors or in a well-ventilated place. Wear cold insulating gloves, face shield, and eye protection. Use a back flow preventive device in the piping. DO NOT change or force fit connections. Close valve after each use and when empty. Always keep containers in upright position. WARNING WARNING DO NOT REMOVE THIS PRODUCT LABEL PRINTED BY RATERMANN MFG., INC. www.rmiorder.com FIRST AID ALWAYS KEEP CONTAINER IN UPRIGHT POSITION. READ AND FOLLOW THE SAFETY DATA SHEET (SDS) BEFORE USE. CAS: 7727-37-9 2 NON-FLAMMABLE GAS DBG-USP-PK250 8/4/15 (R-K14) XXXXXX Pt # DBG-NNF DANGER MAY CAUSE OR INTENSIFY FIRE; OXIDIZER. CONTAINS REFRIGERATED GAS; MAY CAUSE CRYOGENIC BURNS OR INJURY. MAY CAUSE DROWSINESS OR DIZZINESS. MAY DISPLACE OXYGEN AND CAUSE RAPID SUFFOCATION. Do not handle until all safety precautions have been read and understood. Keep and store away from clothing and other combustible materials. Keep valves and fittings free from grease and oil. Avoid breathing gas. Use and store only outdoors or in a well-ventilated place. Wear cold insulating gloves, face shield, and eye protection. In case of fire: Stop leak if safe to do so. Use a back flow preventive device in the piping. Use only with equipment of compatible materials of construction and rated for cylinder pressure. Use only with equipment cleaned for oxygen service. Avoid spills. Do not walk on or roll equipment over spills. Close valve after each use and when empty. READ AND FOLLOW THE SAFETY DATA SHEET (SDS) BEFORE USE. CAS: 10024-97-2 IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER or doctor/physician if you feel unwell. IF ON SKIN: Thaw frosted parts with lukewarm water. Do not rub affected area. Get immediate medical advice/attention. DO NOT REMOVE THIS PRODUCT LABEL PRINTED BY RATERMANN MFG., INC. www.rmiorder.com FIRST AID ALWAYS KEEP CONTAINER IN UPRIGHT POSITION. NITROUS OXIDE REFRIGERATED LIQUID UN 2201 OXIDIZER 2 5.1 NON-FLAMMABLE GAS (R-K14) XXXXXX Pt # DBG-NO Pt # DBG-O OXYGEN REFRIGERATED LIQUID UN 1073 MAY CAUSE OR INTENSIFY FIRE; OXIDIZER. CONTAINS REFRIGERATED GAS; MAY CAUSE CRYOGENIC BURNS OR INJURY. COMBUSTIBLES IN CONTACT WITH LIQUID OXYGEN MAY EXPLODE ON IGNITION OR IMPACT. Do not handle until all safety precautions have been read and understood. Keep and store away from clothing and other combustible materials. Keep valves and fittings free from grease and oil. Use and store only outdoors or in a well-ventilated place. Wear cold insulating gloves, face shield, and eye protection. In case of fire: Stop leak if safe to do so. Use a back flow preventive device in the piping. Use only with equipment of compatible materials of construction and rated for cylinder pressure. Use only with equipment cleaned for oxygen service. DO NOT change or force fit connections. Avoid spills. Do not walk on or roll equipment over spills. Close valve after each use and when empty. Always keep container in upright position. READ AND FOLLOW THE SAFETY DATA SHEET (SDS) BEFORE USE. CAS: 7782-44-7 OXYGEN 2 IF ON SKIN: Thaw frosted parts with lukewarm water. Do not rub affected area. Get immediate medical advice/attention. DANGER DO NOT REMOVE THIS PRODUCT LABEL PRINTED BY RATERMANN MFG., INC. www.rmiorder.com FIRST AID ALWAYS KEEP CONTAINER IN UPRIGHT POSITION. DBG-O-PK250 8/4/15 UPC CODE XXXXXX (R-K14A) (R-K14) XXXXXX Requirement of SB-26 Medical 3 1/2” Dewar 360˚ Gas Tape Part # Description Roll Length DG-MEDO 3 1/2” Oxygen Dewar 360˚ Gas Tape 250’ Roll DG-MEDN 3 1/2” Nitrogen Dewar 360˚ Gas Tape 250’ Roll DG-MEDNO 3 1/2” Nitrous Oxide Dewar 360˚ Gas Tape 250’ Roll Industrial 3” Dewar 360˚ Gas Tape Part # Description Roll Length DG-TC 3” Carbon Dioxide Dewar 360˚ Gas Tape 250’ Roll DG-TO 3” Oxygen Dewar 360˚ Gas Tape 250’ Roll DG-TN 3” Nitrogen Dewar 360˚ Gas Tape 250’ Roll DG-TA 3” Argon Dewar 360˚ Gas Tape 250’ Roll DG-TH 3” Helium Dewar 360˚ Gas Tape 250’ Roll French Medical 3 1/2” & Industrial 3” Dewar 360˚ Gas Tape Part # Description F-DG-NNF French – 360˚ Tape Nitrogen NF F-DG-NOUSP French – 360˚ Tape Nitrous Oxide USP F-DG-OUSP French – 360˚ Tape Medical 02 F-DG-TCUSP French – 360˚ Tape Carbon Dioxide USP Medical and Gas Tape also available in Spanish, please call for part number. Medical Gas Valve Labels Medical Gas Valve Labels DL-MOPK50 Medical Oxygen (Pt # DL-MOPK10) DL-MNPK50 Medical Nitrogen (Pt # DL-MNPK10) DL-MCO2PK50 Medical Carbon Dioxide (Pt # DL-MCO2PK10) DL-MNOPK50 Medical Nitrous Oxide (Pt # DL-MNOPK10) MEDICAL OXYGEN Pt # DL-MO Pt # DL-MN MEDICAL NITROGEN Pt # DL-MNO MEDICAL NITROUS OXIDE Pt # DL-MCO2 MEDICAL CARBON DIOXIDE Dewar & Medical Gas Labels, 360˚ Wrap Around Tape Please see page 7A 24-26 for a complete list of Dewar Body Labels. Medical and Industrial 360˚ Wrap Around Tape Medical Tape Medical Tape Design to meet FDA Regulation for Medical Dewars Comes in 3 1/2” H x 250 Foot Rolls How to Use • Roll off length needed and cut to desired size • Easy peel off backing 3 1/2” Medical Oxygen Dewar 360˚ Gas Tape Pt # DG-MEDO DL-OVPK50 Vent Valve Label (Pt # DL-OVPK10) DL-OGPK50 Gas Valve Label (Pt # DL-OGPK10) VENT Part # DL-OV Part # DL-OG GAS Dewar Valve Labels Part # for Description Part # for Pkg. of 50 Pkg. of 10 Part # for Description Part # for Pkg. of 50 Pkg. of 10