Ratermann Manufacturing, Inc. Customer Service 1-800-264-7793 y Email [email protected] y Order Online at Web Store www.rmiorder.com 7A-19 HP SIDE WALL LABEL IMPRINTS AND ORDER FORM High Pressure Side Labels OXYGEN COMPRESSED, USP Pt # GMBLC-OUSP-XXX-PK250 COMPRESSED GAS, N.O.S. (81% HELIUM, 15.6% NITROGEN, 3.4% CARBON DIOXIDE) UN1956 FOR USE WITH MEDICAL LASER EQUIPMENT. USE IN ACCORDANCE WITH EQUIPMENT MANUFACTURER’S INSTRUCTIONS. NOT FOR DRUG USE. NOT FOR INHALATION. FOR USE ONLY BY OR UNDER THE SUPERVISION OF A LICENSED PRACTITIONER WHO IS EXPERIENCED IN THE USE OF LASER EQUIPMENT. WARNING: CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED. MAY DISPLACE OXYGEN AND CAUSE RAPID SUFFOCATION. MAY INCREASE RESPIRATION AND HEART RATE. Do not handle until all safety precautions have been read and understood. Avoid breathing gas. Use and store only outdoors or in a well-ventilated place. Use a back flow preventive device in the piping. Use only with equipment rated for cylinder pressure. Close valve after each use and when empty. Protect from sunlight when ambient temperature exceeds 52˚C (125˚F). Read and follow the Safety Data Sheet (SDS) before use. FIRST AID: IF INHALED: Remove person to fresh air and keep comfortable for breathing. Get medical advice/attention. DO NOT REMOVE THIS PRODUCT LABEL. CAS: HELIUM 7440-59-7, NITROGEN 7727-37-9, CARBON DIOXIDE 124-38-9 LASER GAS (R-K14) 2 LOT CYL. EXP. NON-FLAMMABLE GAS YOUR LOGO HERE 1234 Street Name Houston, TX 77007 1-800-000-1234 www.company.com Logo for Label 1 PMS Color # Send Us Your Art Work to: [email protected] Format for Logo – Tiff Format Logo Colors – Pantone Colors List PMS Color(s) Used 2 PMS Color # 3 PMS Color # Order Form High Pressure Side Labels Company Information Company Name: Required Web Address: (optional) Phone: Required * Complete address is a requirement for Industrial and Specialty Gases (per CGA C-7–2014, Section 7.1 OSHA’s Hazard Communication Standard). **Medical Gases – The FDA requires City, State and Zip Code, but allows the street address to be omitted, as long as the company can be located in a city or telephone directory on medical gases. For medical gas labels, our customers have the option of including their full address or just the City, State and Zip Code and this decision is solely at their discretion. (Per FDA CFR Title 21, Sec. 201.1 (i)) Location of Logo (R-K14) COMPRESSED GAS, N.O.S. ( % CARBON DIOXIDE, % OXYGEN, % NITROGEN) UN1956 2 CLINICAL BLOOD GAS CALIBRATION MIXTURE FOR CALIBRATION OF BLOOD GAS ANALYZERS IN ACCORDANCE WITH MANUFACTURER’S INSTRUCTIONS. NOT FOR DRUG USE. NOT FOR INHALATION. WARNING: CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED. MAY DISPLACE OXYGEN AND CAUSE RAPID SUFFOCATION. MAY INCREASE RESPIRATION AND HEART RATE. Do not handle until all safety precautions have been read and under- stood. Avoid breathing gas. Use and store only outdoors or in a well-ventilated place. Use a back flow preventive device in the piping. Use only with equipment of compatible materials of construction and rated for cylinder pressure. Close valve after each use and when empty. Protect from sunlight when ambient temperature exceeds 52˚C (125˚F). Read and follow the Safety Data Sheet (SDS) before use. FIRST AID: IF INHALED: Remove person to fresh air and keep comfortable for breathing. Get medical advice/attention. DO NOT REMOVE THIS PRODUCT LABEL. CAS: CARBON DIOXIDE 124-38-9, OXYGEN 7782-44-7, NITROGEN 7727-37-9 LOT CYL. EXP. NON-FLAMMABLE GAS OXYGEN 2 OXYGEN, COMPRESSED USP UN 1072 C.A.S. NO. 7782-44-7 DANGER: MAY CAUSE OR INTENSIFY FIRE; OXIDIZER. CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED. Do not handle until all safety precautions have been read and understood. Keep and store away from clothing and other combustible materials. Keep valves and fittings free from grease and oil. Use and store only outdoors or in a well-ventilated place. In case of fire: Stop leak if safe to do so. Use a back flow preventive device in the piping. Use only with equipment of compatible materials of construction and rated for cylinder pressure. Use only with equipment cleaned for oxygen service. Open valve slowly. Close valve after each use and when empty. Protect from sunlight when ambient temperature exceeds 52˚C (125˚F). Read and follow the Safety Data Sheet (SDS) before use. DO NOT REMOVE THIS PRODUCT LABEL. WARNING: For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, Rx only. Uninterrupted use of high concentrations of oxygen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful. Do not attempt to use on patients who have stopped breathing unless used in conjunction with resuscitative equipment. Produced by Air Liquefaction. Size Contents Size Contents M6 170 Liters E 6682 Liters C 248 Liters H 6910 Liters D 415 Liters Other Liters (R-K14) Address: Required – Street Number and Name, City, State and Zip Code* ** All logo label orders will be processed after sending a camera-ready proof to approve. NON-FLAMMABLE GAS NITROUS OXIDE USP UN1070 CONTENTS: CU FT LITERS WARNING: DANGER: FIRST AID: Administration of Nitrous Oxide may be hazardous or contraindicated. For use only by or under the supervision of a licensed practitioner who is experienced in the use and administration of Nitrous Oxide and is familiar with the indications, effects, dosages, methods, and frequency and duration of administration, and with the hazards, contraindications and side effects, and the precautions to be taken. MAY CAUSE OR INTENSIFY FIRE; OXIDIZER. CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED. MAY CAUSE DROWSINESS OR DIZZINESS. MAY DISPLACE OXYGEN AND CAUSE RAPID SUFFOCATION. MAY CAUSE FROSTBITE. Do not handle until all safety precautions have been read and understood. Keep and store away from clothing and other combustible materials. Keep valves and fittings free from grease and oil. Avoid breathing gas. Do not get in eyes, on skin, or on clothing. Use and store only outdoors or in a well-ventilated place. In case of fire: Stop leak if safe to do so. Use a back flow preventive device in the piping. Use only with equipment of compatible materials of construction and rated for cylinder pressure. Use only with equipment cleaned for oxygen service. Open valve slowly. Close valve after each use and when empty. Protect from sunlight when ambient temperature exceeds 52˚C (125˚F). Read and follow the Safety Data Sheet (SDS) before use. IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER or doctor/physician if you feel unwell. IF ON SKIN: Thaw frosted parts with lukewarm water. Do not rub affected area. Get immediate medical advice/attention. CAS: 10024-97-2 DO NOT REMOVE THIS PRODUCT LABEL. OXIDIZER 2 5.1 RX Only. USP (R-K14) 114388 High Pressure Side Labels NITROUS OXIDE, USP 5” x 8” Pt # GMBLC-N2OUSP-XXX-PK250 INDIANA OXYGEN COMPANY 6099 West Corporate Way Indianapolis, IN 46278 317-290-0003 High Pressure Side Labels LASER GAS 6” x 4” Pt # GMBLC-LG-XXX-PK250 High Pressure Side Labels CLINICAL BLOOD GAS DOUBLE DIAMOND 6” x 4” Pt # GMBLC-CBG-XXX-PK250 COMPRESSED GASES, FLAMMABLE, N.O.S. UN1954 BIOLOGICAL ATMOSPHERE MIXTURE FOR CULTURE GROWTH. FOR LABORATORY USE ONLY. NOT FOR DRUG USE. NOT FOR INHALATION. DANGER: EXTREMELY FLAMMABLE GAS. CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED. MAY DISPLACE OXYGEN AND CAUSE RAPID SUFFOCATION. MAY FORM EXPLOSIVE MIXTURES WITH AIR. BURNS WITH INVISIBLE FLAME. MIXTURES CONTAINING MORE THAN 5% CARBON DIOXIDE CAN INCREASE RESPIRATION AND HEART RATE. Do not handle until all safety precautions have been read and understood. Keep away from heat, open flames, sparks, hot surfaces. – No smoking. Use and store only outdoors or in a well-ventilated place. Leaking gas fire: Do not extinguish, unless leak can be stopped safely. Eliminate all ignition sources if safe to do so. Use a back flow preventive device in the piping. Use only with equipment rated for cylinder pressure. Do not open valve until connected to equipment prepared for use. Close valve after each use and when empty. Store and use at temperature above 40˚F (4.4˚C). Return with at least 25 PSIG Pressure. Protect from sunlight when ambient temperature exceeds 52˚C (125˚F). Read and follow the Safety Data Sheet (SDS) before use. FIRST AID: IF INHALED: Remove person to fresh air and keep comfortable for breathing. Get medical advice/attention. DO NOT REMOVE THIS PRODUCT LABEL. CAS: HYDROGEN 1333-74-0, NITROGEN 7727-37-9, CARBON DIOXIDE 124-38-9 ANAEROBIC GAS MIXTURE FLAMMABLE GAS 2 (NITROGEN, HYDROGEN, CARBON DIOXIDE) West A ir West A ir 1-866-937-8247 2506 Market Street San Diego, CA 92102 www.westairgases.com (R-K14) 115199 High Pressure Side Labels ANAEROBIC GAS MIXTURE 4” x 6” Pt # GMBLC-AGM-XXX-PK250 NON-FLAMMABLE GAS OXIDIZER 2 5.1 COMPRESSED GAS, OXIDIZING, N.O.S. (CARBON DIOXIDE, NITROGEN, OXYGEN) UN3156 FOR CALIBRATION OF BLOOD GAS ANALYZERS IN ACCORDANCE WITH MANUFACTURER’S INSTRUCTIONS. NOT FOR DRUG USE. NOT FOR INHALATION. DANGER: MAY CAUSE OR INTENSIFY FIRE; OXIDIZER. CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED. MAY INCREASE RESPIRATION AND HEART RATE. Do not handle until all safety precautions have been read and understood. Keep valves and fittings free from grease and oil. Avoid breathing gas. Use and store only outdoors or in a well-ventilated place. Use a back flow preventive device in the piping. Use only with equipment of compatible materials of construction and rated for cylinder pressure. Use only with equip- ment cleaned for oxygen service. Open valve slowly. Close valve after each use and when empty. Protect from sunlight when ambient temperature exceeds 52˚C (125˚F). Read and follow the Safety Data Sheet (SDS) before use. FIRST AID: IF INHALED: Remove person to fresh air and keep comfortable for breathing. Get medical advice/attention. DO NOT REMOVE THIS PRODUCT LABEL. CAS # CARBON DIOXIDE124-38-9, NITROGEN 7727-37-9, OXYGEN 7782-44-7 CLINICAL BLOOD GAS CARBON DIOXIDE, USP NITROGEN, NF OXYGEN, USP West A ir West A ir 1-866-937-8247 2506 Market Street San Diego, CA 92102 www.westairgases.com (R-K14) These are Just a Few Samples of Our High Pressure Cylinder & Cryogenic Labels Available. Please visit www.reliablelabels.com! Custom Imprint Side Labels... Promote Your Brand. High Pressure Side Wall Label Imprints CUSTOM PRINT*** High Pressure Side Labels Part # Description GMBLC-LG-XXX-PK250 Laser Gas / Mixture GMBLC-AGM-XXX-PK250 Anaerobic Gas Mixture GMBLC-CBG-XXX-PK250 Clinical Blood Gas – Double Diamond GMBLC-CBLCM-XXX-PK250 Clinical Blood Gas – Calibration Mixture GMBLC-CBL-CDNIO2-XXX-PK250 Clinical Blood Gas (CO2, NI, O2) GMBLC-N2OUSP-XXX-PK250 Nitrous Oxide, USP Side Wall High Pressure Shoulder Labels GMBLC-CGN2OSO2-XXX-PK250 ComGasOxidNOS (Nitrous Oxide,Sulfur Dioxide) Roll (250) GMBLC-OUSP-XXX-PK250 Cylinder Body Label Oxygen USP, Roll (250) ***One time plate charge .